Exit and Save
ADVANCED FORMATTING
Ì$
-
116
5 Divide Code into Fields
divide code into fields
ÌHF.Î
Read one number in the range 1 to 5 to divide the code into fields.
6 Define Code Fields
define code fields
Each code field length can be set by either:
a
) defining a field separator character to be found in the code itself. In this case you can choose
to discard the code separator character or include it as the last character of the field.
OR BY
b
) defining a match character to be found consecutively repeated in the code itself. In this case
the field ends with the first character that does not match.
OR BY
c
) specifying a specific character length up to the maximum of 99 characters.
OR BY
d
) selecting the last field as variable length (if any).
You must define the same number of fields as selected in step 5, including fields that will
not be transmitted.